AD586
AD586M, AD586S, AD586T
@ T A = 25°C, V IN = 15 V, unless otherwise noted. Specifications in boldface are tested on all production units at final electrical test. Results
from those tests are used to calculate outgoing quality levels. All minimum and maximum specifications are guaranteed, although only
those shown in boldface are tested on all production units, unless otherwise specified.
Table 2.
AD586M
AD586S
AD586T
Parameter
Min
Typ
Max
Min
Typ
Max
Min
Typ
Max
Unit
OUTPUT VOLTAGE
4.998
5.002
4.990
5.010
4.9975
5.0025
V
OUTPUT VOLTAGE
0°C to 70°C
2
ppm/°C
?55°C to +125°C
20
10
ppm/°C
GAIN ADJUSTMENT
+6
?2
+6
?2
+6
?2
%
%
10.8 V < +V IN < 36 V
T MIN to T MAX
11.4 V < +V IN < 36 V
±100
μV/V
T MIN to T MAX
±150
±150
μV/V
Sourcing 0 mA < I OUT < 10 mA
25°C
T MIN to T MAX
100
100
150
150
150
150
μV/mA
μV/mA
Sinking ?10 mA < I OUT < 0 mA
25°C
400
400
400
μV/mA
QUIESCENT CURRENT
2
3
2
3
2
3
mA
POWER CONSUMPTION
30
30
30
mW
OUTPUT NOISE
0.1 Hz to 10 Hz
Spectral Density,
4
100
4
100
4
100
μV p-p
nV/√Hz
100 Hz
LONG-TERM STABILITY
15
15
15
ppm/1000 hr
SHORT-CIRCUIT
CURRENT-TO-GROUND
45
60
45
60
45
60
mA
TEMPERATURE RANGE
0
?40
70
+85
?55
?55
+125
+125
?55
?55
+125
+125
°C
°C
1
2
3
Maximum output voltage drift is guaranteed for all packages and grades. CERDIP packaged parts are also 100°C production tested.
Lower row shows specified performance for A and B grades.
The operating temperature range is defined as the temperature extremes at which the device will still function. Parts may deviate from their specified performance
outside their specified temperature range.
Rev. G | Page 4 of 16